Polyfoam ECO High Impact and Upstand Board
For the thermal insulation and protection of upstands in flat
roofing
Description
Polyfoam ECO High Impact and Upstand Board is a rigid extruded
polystyrene board with Zero Ozone Depletion Potential (ODP) and a
Global Warming Potential (GWP) of less than five.
Polyfoam ECO High Impact and Upstand Board is a laminate of
Polyfoam ECO high performance extruded polystyrene (xps) with a
tough, weather resistant facing board.
Polyfoam ECO High Impact and Upstand Board is square edged.
Application
Polyfoam ECO High Impact and Upstand Board is used for the
thermal insulation and protection of upstands in flat roofing. It
can also be used as a lining, where strength, fire performance and
potential for easy cleaning are important, such as in agricultural
buildings and flat roofs.
Standards
The extruded polystyrene content of Polyfoam ECO High
Impact and Upstand Board is manufactured in accordance with BS EN
13164:2008, EN 16001:2009 Energy Management Systems, OHSAS
18001:2007 Occupational Health and Safety Management Systems, ISO
14001:2004 Environmental Management Systems, and ISO 9001:2008
Quality Management Systems, as certified by Bureau
Veritas.
Thermal Performance
The extruded polystyrene content of Polyfoam ECO High
Impact and Upstand Board has a thermal conductivity of 0.035
W/mK.
- Integral weather resistant
facing
- Capable of solving many design problems
- Excellent thermal performance
- Structurally stable
- Easy to install one-piece facing and insulation solution
Durability
The continuous service temperature limits of Polyfoam ECO High
Impact and Upstand Boards are -20 to +70ºC.
Environmental
Polyfoam ECO High Impact and Upstand Board is manufactured with
a GWP<5, is free from CFCs, HCFCs and any other material with
ozone depletion potential in its manufacture and content, and
represents no known threat to the environment.
The xps content of Polyfoam ECO High Impact and Upstand Board is
non bio-degradable and 100% recyclable.
Compression resistance
Polyfoam ECO High Impact and Upstand Boards are highly resistant
to compression and withstand both occasional and long term static
loads.
Load bearing construction elements should be designed to
adequately support the combination of imposed and dead loads
without creating excessive deflection.
Moisture resistance
Polyfoam ECO High Impact and Upstand Board is resistant to
moisture absorption and can be laid in standing water or up against
wet concrete with negligible impact on the performance of the
product.
Moisture absorption
Polyfoam ECO High Impact and Upstand Board has a moisture
absorption of 1.1% by volume when tested in accordance with EN
12087.
Vapour resistivity
Polyfoam ECO High Impact and Upstand Board has a water vapour
resistivity of 600MNs/g.m.
Fire performance
Polyfoam ECO insulation contains a flame retardant which
inhibits localised ignition. Polyfoam ECO High Impact and Upstand
Board is faced with a 6mm weather resistant facing which offers
excellent fire performance as a facing material and is classified
as Class 1 Surface Spread of Flame to BS 476: Part 7: 1987.
Handling and storage
The boards are easy to handle and protective clothing is not
required, however, when cutting through the facing material it is
advisable to wear a facemask to guard against dust. Polyfoam ECO
High Impact and Upstand Board is supplied on pallets, labelled with
identifying product and manufacturing data and wrapped in a
polythene shroud for temporary protection during transit and on
site. Ensure the boards are not stored close to open flames or
other ignition sources, also avoid volatile compounds and chemicals
such as solvents. Polyfoam ECO products should not be left exposed
to prolonged sunlight as this will result in surface degradation.
Where outside storage for extended periods is required cover with
opaque/light coloured sheeting. The facing board on Polyfoam ECO
High Impact and Upstand Board should have edges and corners
protected to prevent chipping.
Product Data
| Thickness
(mm) |
Thermal conductivity
(W/mK) |
Thermal resistance
(m2K/W) |
Nominal Density of
Insulation (kg/m3) |
Compressive Strength
(kPa) |
Length (mm) |
Width (mm) |
| 50 / 6 |
0.035 / 0.41 |
1.40 / 0.014 |
30 |
300 |
2400 |
1200 |
All dimensions are nominal