EPD BLOWING WOOL INSULATION Λ 0.032 - 0.033 W/MK

ECOSE® Binder Technology Sustainable Performance

Environmental Product Declarations

Blowing wool insulation λ 0.032 - 0.033 W/mK

Products covered: Supafil® Frame (0.033W/mK / 30kg/m3 density).

ENVIRONMENTAL IMPACT POTENTIALS

The declared unit is 1m2 at 100mm thickness

INDICATOR

UNIT

TOTAL A1-A3 

A4 

A5 (Loft) 

A5 (Timber Frame)

A5 (Cavity)

C2

C4

GLOBAL WARMING POTENTIAL (GWP) 

KG CO2 EQ. 

2.92E+00

5.06E-02

1.03E-01

1.10E-01

1.43E-01

3.15E-02 1.61E-02

STRATOSPHERIC OZONE LAYER DEPLETION POTENTIAL (ODP) 

KG CFC 11 EQ. 

3.00E-07

9.11E-09

7.59E-09

8.79E-09

1.48E-08

5.69E-09 5.30E-09

ACIDIFICATION POTENTIAL (AP) 

KG SO2 EQ. 

6.93E-03

1.25E-04

2.13E-04

2.64E-04

5.10E-04

1.19E-04 1.18E-04

EUTROPHICATION POTENTIAL (EP) 

KG PO43- EQ. 

9.00E-04

1.59E-05

3.48E-05

4.56E-05

9.98E-05

2.09E-05 2.04E-05

FORMATION POTENTIAL OF TROPOSPHERIC OZONE (POCP) 

KG C2H4 EQ. 

4.20E-04

7.88E-06

1.04E-05

1.18E-05

1.84E-05

5.26E-06 5.83E-06

ABIOTIC RESOURCES DEPLETION POTENTIAL – ELEMENTS (ADPE) 

KG SB EQ. 

1.66E-04

4.88E-07

3.29E-06

3.30E-06

3.32E-06

4.09E-07 5.38E-08

ABIOTIC RESOURCES DEPLETION POTENTIAL – FOSSIL RESOURCES (ADPF) 

MJ 

4.96E+01

7.65E-01

1.12E+00

1.22E+00

1.69E+00

4.74E-01 4.54E-01

RESOURCE USE

The declared unit is 1m2 at 100mm thickness

INDICATOR

UNIT

TOTAL A1-A3

A4

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2

C4

PRIMARY ENERGY RESOURCES – RENEWABLE 

(PERE) 

USE AS ENERGY CARRIER 

MJ, 

NET CALORIFIC VALUE 

7.83E-01

9.24E-03

2.28E-02 2.34E-02

2.62E-02

7.23E-03

1.17E-02

 

USED AS RAW MATERIALS 

MJ, 

NET CALORIFIC VALUE 

3.23E-01

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

 

Total

MJ, 

NET CALORIFIC VALUE 

1.11E+00

9.24E-03

2.28E-02 2.34E-02

2.62E-02

7.23E-03

1.17E-02

PRIMARY ENERGY RESOURCES – 

NON-RENEWABLE 

(PENRE) 

USE AS ENERGY CARRIER 

MJ, 

NET CALORIFIC VALUE 

6.06E+01

7.76E-01

1.36E+00 1.45E+00

1.93E+00

4.85E-01

4.61E-01

 

USED AS RAW MATERIALS

MJ, 

NET CALORIFIC VALUE 

7.19E-01

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

 

Total

MJ, 

NET CALORIFIC VALUE 

6.13E+01

7.76E-01

1.36E+00 1.45E+00

1.93E+00

4.85E-01

4.61E-01

SECONDARY MATERIAL (SM) 

 

KG 

2.14E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

RENEWABLE SECONDARY FUELS (RSF) 

MJ, 

NET CALORIFIC VALUE 

0.00E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

NON-RENEWABLE SECONDARY FUELS (NRSF) 

MJ, 

NET CALORIFIC VALUE 

0.00E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

NET USE OF FRESH WATER (FW) 

M3  

1.82E-02

1.41E-04

3.90E-04 4.20E-04

4.80E-04

9.45E-05

5.10E-04

WASTE PRODUCTION

The declared unit is 1m2 at 100mm thickness

INDICATOR 

UNIT 

TOTAL A1-A3 

A4 

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2 

C4 

HAZARDOUS WASTE DISPOSED (HW) 

KG 

5.40E-04

2.02E-05

3.35E-05 4.87E-05

1.25E-04

1.32E-05

2.71E-05

NON-HAZARDOUS WASTE DISPOSED (NHW) 

KG 

4.29E-01

3.62E-02

8.41E-02 8.41E-02

8.44E-02

1.85E-02

3.00E+00

RADIOACTIVE WASTE DISPOSED (RW) 

KG 

3.00E-04

5.16E-06

7.12E-06 7.80E-06

1.12E-05

3.26E-06

3.02E-06

OTHER OUTPUT FLOWS

The declared unit is 1m2 at 100mm thickness

INDICATOR 

UNIT 

TOTAL A1-A3 

A4 

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2 

C4 

COMPONENTS FOR REUSE (CR) 

KG 

0.00E+00 

0.00E+00 

0.00E+00  0.00E+00 

0.00E+00 

0.00E+00 

0.00E+00 

MATERIAL FOR RECYCLING (MR) 

KG 

1.30E-04

4.31E-07

2.65E-06 2.68E-06

2.82E-06

2.57E-07

3.16E-07

MATERIALS FOR ENERGY RECOVERY (MER) 

KG 

9.52E-13

1.83E-14

1.96E-14 2.03E-14

2.37E-14

1.41E-14

1.35E-14

EXPORTED ENERGY (EE) 

MJ 

0.00E+00 

0.00E+00 

0.00E+00  0.00E+00 

0.00E+00 

0.00E+00 

0.00E+00