EPD BLOWING WOOL INSULATION Λ 0.034 - 0.036 W/MK

ECOSE® Binder Technology Sustainable Performance

Environmental Product Declarations

Blowing wool insulation λ 0.034 - 0.036 W/mK

Products covered: Supafil® Frame (0.034W/mK / 26kg/m3 density), Supafil® 34, Supafil® CarbonPlus.

ENVIRONMENTAL IMPACT POTENTIALS

The declared unit is 1m2 at 100mm thickness

INDICATOR

UNIT

TOTAL A1-A3 

A4 

A5 (Loft) 

A5 (Timber Frame)

A5 (Cavity)

C2

C4

GLOBAL WARMING POTENTIAL (GWP) 

KG CO2 EQ. 

2.33E+00

4.05E-02

8.27E-02

8.80E-02

1.15E-01

2.52E-02 1.28E-02

STRATOSPHERIC OZONE LAYER DEPLETION POTENTIAL (ODP) 

KG CFC 11 EQ. 

2.40E-07

7.28E-09

6.07E-09

7.03E-09

1.18E-08

4.55E-09 4.24E-09

ACIDIFICATION POTENTIAL (AP) 

KG SO2 EQ. 

5.54E-03

9.98E-05

1.71E-04

2.11E-04

4.08E-04

9.51E-05 9.47E-05

EUTROPHICATION POTENTIAL (EP) 

KG PO43- EQ. 

7.20E-04

1.27E-05

2.78E-05

3.65E-05

7.98E-05

1.67E-05 1.63E-05

FORMATION POTENTIAL OF TROPOSPHERIC OZONE (POCP) 

KG C2H4 EQ. 

3.36E-04

6.31E-06

8.35E-06

9.41E-06

1.47E-05

4.21E-06 4.66E-06

ABIOTIC RESOURCES DEPLETION POTENTIAL – ELEMENTS (ADPE) 

KG SB EQ. 

1.33E-04

3.90E-07

2.64E-06

2.64E-06

2.66E-06

3.27E-07 4.30E-08

ABIOTIC RESOURCES DEPLETION POTENTIAL – FOSSIL RESOURCES (ADPF) 

MJ 

3.97E+01

6.12E-01

8.96E-01

9.72E-01

1.35E+00 3.79E-01 3.63E-01

RESOURCE USE

The declared unit is 1m2 at 100mm thickness

INDICATOR

UNIT

TOTAL A1-A3

A4

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2

C4

PRIMARY ENERGY RESOURCES – RENEWABLE 

(PERE) 

USE AS ENERGY CARRIER 

MJ, 

NET CALORIFIC VALUE 

6.26E-01

7.39E-03

1.83E-02 1.87E-02

2.10E-02

5.78E-03

9.36E-03

 

USED AS RAW MATERIALS 

MJ, 

NET CALORIFIC VALUE 

2.59E-01

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

 

Total

MJ, 

NET CALORIFIC VALUE 

8.85E-01

7.93E-03

1.83E-02 1.87E-02

2.10E-02

5.78E-03

9.36E-03

PRIMARY ENERGY RESOURCES – 

NON-RENEWABLE 

(PENRE) 

USE AS ENERGY CARRIER 

MJ, 

NET CALORIFIC VALUE 

4.85E+01

6.21E-01

1.08E+00 1.16E+00

1.55E+00

3.88E-01

3.69E-01

 

USED AS RAW MATERIALS

MJ, 

NET CALORIFIC VALUE 

5.75E-01

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

 

Total

MJ, 

NET CALORIFIC VALUE 

4.91E+01

6.21E-01

1.08E+00 1.16E+00

1.55E+00

3.88E-01

3.69E-01

SECONDARY MATERIAL (SM) 

 

KG 

1.71E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

RENEWABLE SECONDARY FUELS (RSF) 

MJ, 

NET CALORIFIC VALUE 

0.00E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

NON-RENEWABLE SECONDARY FUELS (NRSF) 

MJ, 

NET CALORIFIC VALUE 

0.00E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

NET USE OF FRESH WATER (FW) 

M3  

1.46E-02

1.13E-04

3.12E-04 3.36E-04

3.84E-04

7.56E-05

4.08E-04

WASTE PRODUCTION

The declared unit is 1m2 at 100mm thickness

INDICATOR 

UNIT 

TOTAL A1-A3 

A4 

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2 

C4 

HAZARDOUS WASTE DISPOSED (HW) 

KG 

4.32E-04

1.62E-05

2.68E-05 3.90E-05

1.00E-04

1.06E-05

2.17E-05

NON-HAZARDOUS WASTE DISPOSED (NHW) 

KG 

3.43E-01

2.90E-02

6.73E-02 6.73E-02

6.75E-02

1.48E-02

2.40E+00

RADIOACTIVE WASTE DISPOSED (RW) 

KG 

2.40E-04

4.13E-06

5.70E-06 6.24E-06

8.94E-06

2.61E-06

2.41E-06

OTHER OUTPUT FLOWS

The declared unit is 1m2 at 100mm thickness

INDICATOR 

UNIT 

TOTAL A1-A3 

A4 

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2 

C4 

COMPONENTS FOR REUSE (CR) 

KG 

0.00E+00 

0.00E+00 

0.00E+00  0.00E+00 

0.00E+00 

0.00E+00 

0.00E+00 

MATERIAL FOR RECYCLING (MR) 

KG 

1.04E-04

3.45E-07

2.12E-06 2.14E-06

2.26E-06

2.05E-07

2.52E-07

MATERIALS FOR ENERGY RECOVERY (MER) 

KG 

7.61E-13

1.47E-14

1.57E-14 1.62E-14

1.90E-14

1.13E-14

1.08E-14

EXPORTED ENERGY (EE) 

MJ 

0.00E+00 

0.00E+00 

0.00E+00  0.00E+00 

0.00E+00 

0.00E+00 

0.00E+00