EPD BLOWING WOOL INSULATION Λ 0.037 - 0.042 W/MK

ECOSE® Binder Technology Sustainable Performance

Environmental Product Declarations

Blowing wool insulation λ 0.037 - 0.042 W/mK

Products covered: Supafil® 40, Supafil® Frame (0.038W/mK / 19kg/m3 density), Supafil® Party Wall.

ENVIRONMENTAL IMPACT POTENTIALS

The declared unit is 1m2 at 100mm thickness

INDICATOR

UNIT

TOTAL A1-A3 

A4 

A5 (Loft) 

A5 (Timber Frame)

A5 (Cavity)

C2

C4

GLOBAL WARMING POTENTIAL (GWP) 

KG CO2 EQ. 

1.65E+00

2.87E-02

5.86E-02

6.24E-02

8.13E-02

1.79E-02 9.10E-03

STRATOSPHERIC OZONE LAYER DEPLETION POTENTIAL (ODP) 

KG CFC 11 EQ. 

1.70E-07

5.16E-09

4.30E-09

4.98E-09

8.37E-09 3.22E-09 3.01E-09

ACIDIFICATION POTENTIAL (AP) 

KG SO2 EQ. 

3.93E-03

7.07E-05

1.21E-04

1.49E-04

2.89E-04

6.74E-05 6.71E-05

EUTROPHICATION POTENTIAL (EP) 

KG PO43- EQ. 

5.10E-04

9.01E-06

1.97E-05

2.59E-05

5.65E-05

1.19E-05 1.15E-05

FORMATION POTENTIAL OF TROPOSPHERIC OZONE (POCP) 

KG C2H4 EQ. 

2.38E-04

4.47E-06

5.91E-06

6.67E-06

1.04E-05

2.98E-06 3.30E-06

ABIOTIC RESOURCES DEPLETION POTENTIAL – ELEMENTS (ADPE) 

KG SB EQ. 

9.39E-05

2.77E-07

1.87E-06

1.87E-06

1.88E-06 2.32E-07 3.05E-08

ABIOTIC RESOURCES DEPLETION POTENTIAL – FOSSIL RESOURCES (ADPF) 

MJ 

2.81E+01

4.34E-01

6.35E-01

6.89E-01 9.59E-01 2.69E-01 2.57E-01

RESOURCE USE

The declared unit is 1m2 at 100mm thickness

INDICATOR

UNIT

TOTAL A1-A3

A4

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2

C4

PRIMARY ENERGY RESOURCES – RENEWABLE 

(PERE) 

USE AS ENERGY CARRIER 

MJ, 

NET CALORIFIC VALUE 

4.43E-01

5.24E-03

1.29E-02 1.33E-02

1.48E-02

4.10E-03

6.63E-03

 

USED AS RAW MATERIALS 

MJ, 

NET CALORIFIC VALUE 

1.83E-01

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

 

Total

MJ, 

NET CALORIFIC VALUE 

6.27E-01

5.24E-03

1.29E-02 1.33E-02

1.48E-02

4.10E-03

6.63E-03

PRIMARY ENERGY RESOURCES – 

NON-RENEWABLE 

(PENRE) 

USE AS ENERGY CARRIER 

MJ, 

NET CALORIFIC VALUE 

3.44E+01

4.40E-01

7.68E-01 8.22E-01

1.10E+00

2.75E-01

2.61E-01

 

USED AS RAW MATERIALS

MJ, 

NET CALORIFIC VALUE 

4.07E-01

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

 

Total

MJ, 

NET CALORIFIC VALUE 

3.48E+01

4.40E-01

7.68E-01 8.22E-01

1.10E+00

2.75E-01

2.61E-01

SECONDARY MATERIAL (SM) 

 

KG 

1.21E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

RENEWABLE SECONDARY FUELS (RSF) 

MJ, 

NET CALORIFIC VALUE 

0.00E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

NON-RENEWABLE SECONDARY FUELS (NRSF) 

MJ, 

NET CALORIFIC VALUE 

0.00E+00

0.00E+00

0.00E+00 0.00E+00

0.00E+00

0.00E+00

0.00E+00

NET USE OF FRESH WATER (FW) 

M3  

1.03E-02

8.02E-05

2.21E-04 2.38E-04

2.72E-04

5.36E-05

2.89E-04

WASTE PRODUCTION

The declared unit is 1m2 at 100mm thickness

INDICATOR 

UNIT 

TOTAL A1-A3 

A4 

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2 

C4 

HAZARDOUS WASTE DISPOSED (HW) 

KG 

3.06E-04

1.14E-05

1.90E-05 2.76E-05

7.09E-05

7.48E-06

1.54E-05

NON-HAZARDOUS WASTE DISPOSED (NHW) 

KG 

2.43E-01

2.05E-02

4.77E-02 4.77E-02

4.78E-02

1.05E-02

1.70E+00

RADIOACTIVE WASTE DISPOSED (RW) 

KG 

1.70E-04

2.93E-06

4.04E-06 4.42E-06

6.33E-06

1.88E-06

1.71E-06

OTHER OUTPUT FLOWS

The declared unit is 1m2 at 100mm thickness

INDICATOR 

UNIT 

TOTAL A1-A3 

A4 

A5 (Loft) A5 (Timber Frame)

A5 (Cavity)

C2 

C4 

COMPONENTS FOR REUSE (CR) 

KG 

0.00E+00 

0.00E+00 

0.00E+00  0.00E+00 

0.00E+00 

0.00E+00 

0.00E+00 

MATERIAL FOR RECYCLING (MR) 

KG 

7.38E-05

2.44E-07

1.50E-06 1.52E-06

1.60E-06

1.45E-07

1.79E-07

MATERIALS FOR ENERGY RECOVERY (MER) 

KG 

5.39E-13

1.04E-14

1.11E-14 1.15E-14

1.35E-14

7.98E-15

7.64E-15

EXPORTED ENERGY (EE) 

MJ 

0.00E+00 

0.00E+00 

0.00E+00  0.00E+00 

0.00E+00 

0.00E+00 

0.00E+00