Environmental performance
Products covered: Rocksilk® RS140
ENVIRONMENTAL IMPACTSThe declared unit is 1m2 at 50mm thickness |
||||||||||
Parameter |
Unit |
A1-3 |
A4 |
A5 |
B1-B7 |
C1 |
C2 |
C3 |
C4 |
D** |
GWP-fossil |
kg CO2 eq. |
1.02E+01 |
3.51E-01 |
2.49E-01 |
0.00E+00 |
0.00E+00 |
2.49E-02 |
0.00E+00 |
1.06E-01 |
-2.15E-01 |
GWP-biogenic |
kg CO2 eq. |
-1.15E+00 |
-5.85E-04 |
4.87E-01 |
0.00E+00 |
0.00E+00 |
-4.22E-05 |
0.00E+00 |
-8.42E-03 |
-5.02E-04 |
GWP-luluc |
kg CO2 eq. |
2.53E-02 |
2.82E-03 |
5.00E-04 |
0.00E+00 |
0.00E+00 |
2.03E-04 |
0.00E+00 |
3.06E-04 |
-1.31E-04 |
GWP-total |
kg CO2 eq. |
9.08E+00 |
3.53E-01 |
7.37E-01 |
0.00E+00 |
0.00E+00 |
2.51E-02 |
0.00E+00 |
9.81E-02 |
-2.16E-01 |
ODP |
kg CFC 11 eq. |
4.06E-14 |
6.40E-17 |
2.73E-11 |
0.00E+00 |
0.00E+00 |
4.61E-18 |
0.00E+00 |
3.93E-16 |
-2.79E-13 |
AP |
mol H+ eq. |
5.31E-02 |
8.96E-04 |
1.13E-03 |
0.00E+00 |
0.00E+00 |
1.53E-04 |
0.00E+00 |
7.62E-04 |
-3.47E-04 |
EP-freshwater |
kg P eq. |
4.77E-05 |
1.06E-06 |
9.59E-07 |
0.00E+00 |
0.00E+00 |
7.65E-08 |
0.00E+00 |
1.82E-07 |
-1.15E-06 |
EP-freshwater [1] |
kg P eq. |
1.46E-04 |
3.25E-06 |
2.94E-06 |
0.00E+00 |
0.00E+00 |
2.34E-07 |
0.00E+00 |
5.58E-07 |
-3.52E-06 |
EP-marine |
kg N eq. |
5.93E-03 |
3.83E-04 |
1.40E-04 |
0.00E+00 |
0.00E+00 |
7.40E-05 |
0.00E+00 |
1.96E-04 |
-1.01E-04 |
EP-terrestrial |
mol N eq. |
1.43E-01 |
4.31E-03 |
3.19E-03 |
0.00E+00 |
0.00E+00 |
8.19E-04 |
0.00E+00 |
2.15E-03 |
-1.09E-03 |
POCP |
kg NMVOC eq. |
1.36E-02 |
1.07E-03 |
3.30E-04 |
0.00E+00 |
0.00E+00 |
2.03E-04 |
0.00E+00 |
5.94E-04 |
-2.92E-04 |
ADP- minerals&metals* |
kg Sb eq. |
1.23E-06 |
2.82E-08 |
2.36E-08 |
0.00E+00 |
0.00E+00 |
2.03E-09 |
0.00E+00 |
9.53E-09 |
-3.18E-08 |
ADP-fossil* |
MJ |
1.02E+02 |
4.65E+00 |
2.03E+00 |
0.00E+00 |
0.00E+00 |
3.35E-01 |
0.00E+00 |
1.39E+00 |
-3.74E+00 |
WDP |
m3 |
6.30E-01 |
3.40E-03 |
6.76E-02 |
0.00E+00 |
0.00E+00 |
2.45E-04 |
0.00E+00 |
1.11E-02 |
-1.86E-02 |
Acronyms |
GWP-fossil = Global Warming Potential fossil fuels; GWP-biogenic = Global Warming Potential biogenic; GWP-luluc = Global Warming Potential land use and land use change; ODP = Depletion potential of the stratospheric ozone layer; AP = Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment; EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-minerals&metals = Abiotic depletion potential for non-fossil resources; ADP-fossil = Abiotic depletion for fossil resources potential; WDP = Water (user) deprivation potential, deprivation-weighted water consumption |
**: [Life Cycle D stage covers benefits and loads beyond the system boundary stage (reuse, recovery and recycling potential) therefore, when summing up results, this stage should be considered separately.
*Disclaimer: the results of this environmental impact indicator shall be used with care as the uncertainties of these results are high or as there is limited experience with the indicator.
EN 15804:2012+A2:2019 specifies that the unit for the indicator for Eutrophication aquatic freshwater shall be KG PO4 eq. although the reference given (“EUTREND model, Strujis et al. 2009b as implemented in ReCiPe”) uses the unit kg P eq. until this has been corrected, results shall be given in both kg PO4 eq and kg P eq. in the EPD.
Potential environmental impact – additional mandatory and voluntary indicators
The declared unit is 1m2 at 50mm thickness
Indicator |
Unit |
Tot.A1-A3 |
A4 |
A5 |
B1-B7 |
C1 |
C2 |
C3 |
C4 |
D |
GWP-GHG[2] |
kg CO2 eq. |
1.01E+01 |
3.48E-01 |
2.48E-01 |
0.00E+00 |
0.00E+00 |
2.47E-02 |
0.00E+00 |
1.05E-01 |
-2.13E-01 |
The indicator includes all greenhouse gasses included in GWP-total but excludes biogenic carbon dioxide uptake and emissions and biogenic carbon stored in the product. This indicator is thus equal to the GWP indicator originally defined in EN 15804:2012+A1:2013.
Additional environmental impact indicators like PM [Disease incidences], IR (kBq U235 eq.], ETF-fw [CTUe], HTP-c [CTUh], HTP-nc [CTUh] and SQP [Pt] are not declared (ND) but were calculated and can be provided on request.
Use of resources: 1m² of Rock Mineral Wool Rocksilk® RS140 with a thickness of 50 mm with R value of 1.47 m2K/W.
RESOURCES USEThe declared unit is 1m2 at 50mm thickness |
||||||||||
Parameter |
Unit |
A1-3 |
A4 |
A5 |
B1-B7 |
C1 |
C2 |
C3 |
C4 |
D* |
PERE [MJ] |
MJ |
1.86E+01 |
2.69E-01 |
3.14E-01 |
0.00E+00 |
0.00E+00 |
1.94E-02 |
0.00E+00 |
1.82E-01 |
-2.37E+00 |
PERM [MJ] |
MJ |
1.02E+01 |
0.00E+00 |
6.47E-02 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
PERT [MJ] |
MJ |
2.88E+01 |
2.69E-01 |
3.79E-01 |
0.00E+00 |
0.00E+00 |
1.94E-02 |
0.00E+00 |
1.82E-01 |
-2.37E+00 |
PENRE [MJ] |
MJ |
1.01E+02 |
4.67E+00 |
2.03E+00 |
0.00E+00 |
0.00E+00 |
3.37E-01 |
0.00E+00 |
1.39E+00 |
-3.74E+00 |
PENRM [MJ] |
MJ. |
9.21E-01 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
PENRT [MJ] |
MJ |
1.02E+02 |
4.67E+00 |
2.03E+00 |
0.00E+00 |
0.00E+00 |
3.37E-01 |
0.00E+00 |
1.39E+00 |
-3.74E+00 |
SM |
kg |
2.20E+00 |
0.00E+00 |
4.41E-02 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
RSF |
MJ |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
NRSF |
MJ |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
FW |
m3 |
2.56E-02 |
3.13E-04 |
1.77E-03 |
0.00E+00 |
0.00E+00 |
2.26E-05 |
0.00E+00 |
3.51E-04 |
-7.98E-04 |
Acronyms |
PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non-renewable primary energy excluding non- renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials; PENRT = Total use of non-renewable primary energy re-sources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water |
*:[Life Cycle D stage covers benefits and loads beyond the system boundary stage (reuse, recovery and recycling potential) therefore, when summing up results, this stage should be considered separately.
Waste production and output flows: 1m² of Rock Mineral Wool Rocksilk® RS140 with a thickness of 50mm with R value of 1.47 m2K/W.
OUTPUT FLOWS AND WASTE CATEGORIESThe declared unit is 1m2 at 50mm thickness |
||||||||||
Parameter |
Unit |
A1-3 |
A4 |
A5 |
B1-B7 |
C1 |
C2 |
C3 |
C4 |
D* |
Hazardous waste disposed |
kg |
2.69E-07 |
2.16E-07 |
5.33E-09 |
0.00E+00 |
0.00E+00 |
1.56E-08 |
0.00E+00 |
2.12E-08 |
-1.42E-09 |
Non-hazardous waste disposed |
kg |
9.10E-01 |
7.40E-04 |
1.62E-01 |
0.00E+00 |
0.00E+00 |
5.34E-05 |
0.00E+00 |
7.01E+00 |
-1.51E-03 |
Radioactive waste disposed |
kg |
3.90E-03 |
8.61E-06 |
6.90E-05 |
0.00E+00 |
0.00E+00 |
6.20E-07 |
0.00E+00 |
1.58E-05 |
-2.24E-04 |
Components for re-use |
kg |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
Material for recycling |
kg |
0.00E+00 |
0.00E+00 |
1.94E-01 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
Materials for energy recovery |
kg |
0.00E+00 |
0.00E+00 |
2.91E-01 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
Exported energy, electricity |
MJ |
0.00E+00 |
0.00E+00 |
7.95E-01 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
Exported energy, thermal |
MJ |
0.00E+00 |
0.00E+00 |
1.53E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
0.00E+00 |
*:[Life Cycle D stage covers benefits and loads beyond the system boundary stage (reuse, recovery and recycling potential) therefore, when summing up results, this stage should be considered separately.